- Real distance adjustment
1. Fix the transmitter and receiver on both sides of the device, aligning the wire ends.
2. Press the trigger button and adjust the receiving end first to turn on its indicator light.
3. Continue to adjust gradually until it reaches the normal working distance, and stop adjusting.
- Calibration deviation
On the basis of adjusting the actual distance, press the trigger button and adjust the transmitter to turn on its indicator light
2. Gradually adjust and align with the receiving end light.
3. Adjust repeatedly until the signals of the lights on both sides are consistent and show a stable state.
- Calibration sensitivity
1. Reset the safety light curtains, press and hold the send button, then press the receive button to maintain stability.
2. Press the TEST button on the safety light curtains receiver to enter the testing mode.
3. Adjust the POWER knob on the transmitting end to make the LED light on the receiving end light up, which gradually increases the sensitivity.
Press the TEST button three times in a row to enter the secondary calibration state.
5. Place the safety light curtains at a close distance (1-2cm), press and hold the emission button, release the button, and repeatedly adjust the POWER knob to make the LED light on the receiving end steadily light up and make a sound.
- Application adjustment
1. Adjust the installation position of the safety light curtains to protect the equipment.
2. According to the actual work situation, increase or decrease the sensitivity appropriately to ensure safety.
The above is a detailed introduction to the adjustment method of the safety light curtains.