Fiber Optic Amplifier

Fiber Optic Amplifier
Details:
GFO-CR11 Series Intelligent color Fiber Optic Amplifier

1. Extremely small detection capability, easily identifying tiny objects, micropores, or subtle positional changes

2. Superior environmental adaptability and interference resistance, unaffected by electromagnetic interference, ambient light, or vibration

3. Flexible and compact installation features; the sensor head and amplifier are separate, and the fiber optic probe has various shapes and is flexible, allowing easy installation in locations inaccessible to traditional sensors, such as robotic arms and confined spaces

4. Extremely fast response speed; boasts microsecond-level ultra-high-speed response, perfectly matching the pace of high-speed production lines

5. Intelligent teaching and stabilization compensation; features one-button teaching and multi-level sensitivity adjustment
Send Inquiry
Download
Description
Technical Parameters
Size & Wiring

Main Features

 

1. The Fiber Optic Amplifier comes with automatic light compensation technology, effectively ensuring the stability of detection;

2. Intelligent adjustment, simple and stable;

3. Customized development services can be provided according to the on-site needs of users;

4. Adequate inventory, quick response, and fast delivery;

5. Say goodbye to tedious operations and easily demonstrate with one click automatic teaching;

6. With built-in light compensation function, it has strong adaptability and reduces maintenance troubles;

7. The response speed is adjustable in 5th gear, with a small margin of error;

8. Red green numerical comparison display, easy to set up.

 

Fiber Optic Amplifier

 

Advantages on Fiber Optic Amplifier

 

  • Unlimited installation location, high degree of flexibility

Using flexible optical fiber, it can be easily installed in machine gaps or confined spaces.

 

  • Small object detection

The sensor tip is extremely small, making it easy to detect small objects.

 

  • Excellent environmental resistance

Because the optical fiber cable does not allow current to flow, it is completely unaffected by electrical noise. Using heat-resistant optical fiber components allows detection even in high-temperature locations.

 

Fiber Optic Amplifier
 
Fiber Optic Amplifier
 
Fiber Optic Amplifier
 
Fiber Optic Amplifier
 
Fiber Optic Amplifier
 
Fiber Optic Amplifier
 

 

Garantta Sensor Customer Service

 

1. Flexible Payment Options: Garantta Sensor accepts a variety of payment methods, including T/T (Telegraphic Transfer), PayPal, Western Union, Letter of Credit (L/C), and Trade Assurance. This allows us to meet a wide range of customer needs and preferences.

 

2. Reasonable Delivery Time: Delivery time depends on product availability and the order scheduling. For in-stock of Fiber Optic Amplifiers, delivery is relatively fast (5-7 days). For custom or bulk orders, delivery time is longer (15-20 days).

 

3. Highly Flexible Sales Model: We support end buyers, equipment buyers, and resellers. We offer tiered quotes based on the purchase volume of different buyers, helping customers maximize procurement cost savings.

 

4. Quality Commitment: Garantta Sensor not only 100% tests all Fiber Optic Amplifiers before delivery, but also conducts 100% pre-inspection of incoming materials before production. This demonstrates our factory's commitment to quality control and minimizes the risk of defective products reaching customers.

 

5. Focus on long-term partnerships: Our boss stated that the foundation of each business success is ensuring customer benefits through excellent quality and competitive pricing. For our long-term customers, Garantta offers the most favorable policies and support, including: 1. Maximum discounts on product quotes; 2. Fastest delivery times; 3. Most convenient technical solution consultants; 4. Maximum subsidies and assistance for participating in exhibitions.

exhibition garantta sensor

 

FAQ

 

Q: Precautions for using fiber optic amplifier:

A: 1) It cannot be installed in the following places: direct sunlight, high humidity, places where frost may form, places with corrosive gases, places where there is direct vibration or impact on the body;

2) When using the same wiring tube or slot for power lines, power lines, and photoelectric switches, it may cause misoperation or product damage due to induction. In principle, please separate the wiring or use shielded wires.

4) After the power supply is connected, it can only be tested after more than 200ms. When the load is separated from the power supply of the fiber optic sensor, please make sure to first connect the power supply of the fiber optic sensor;

5) When cutting off the power supply, output pulses may occur, so it is necessary to first cut off the power supply of the load or load line;

6) When using a plug-in type, in order to prevent electric shock or short circuit, please attach a protective patch to the unused connection power terminal;

7) Be sure to cut off the power supply when disassembling and installing the fiber optic amplifier;

8) Please do not apply stretching, compression or other actions while the fiber optic unit is fixed to the amplifier unit;

9) Be sure to cover the protective cover properly when using it;

10) Do not use banana water, gasoline, acetone, or lamp oil for cleaning. Disassembly and assembly of fiber optic sensors: Fiber optic sensors are composed of two components: amplifier unit and fiber optic unit, which are more complex to install compared to inductive sensors and capacitive sensors

 

Hot Tags: fiber optic amplifier, China fiber optic amplifier manufacturers, suppliers, factory, Proximity Sensors for Industrial Automation, photocell beam sensor, optical displacement sensors, fiber optic sensor working, optical fiber sensor types, fiber optic instrumentation system

Detection method Light intensity detection MARK and automatic color matching detection
Light source White LED,4-element light-emitting diode body
Control output 1 output port
Type 1 output port, lead-out type
Reaction time CONTRAST mode 33us, COLOR mode 80us
Output selection LIGHT-ON/DARK-ON (button selection)
Display indicator Operation indicator: red LED, dual digital monitor: dual 7-digit display, threshold (4-digit green LED body indicator) and current value (4-digit red LED body indicator) light up together. Current value range: 0-9999
Delay function Off delay timer/on delay timer/single timer/on delay single timer are selectable. Meter display in duration selectable: 1ms to 9999ms
Control output NPN/PNP open collector 24V, maximum 100mA (main unit only) maximum 20mA (when extension unit is connected, residual voltage: 1V. Sensors with M in the model number are analog output, and the analog voltage ranges from 0-5V. The detection accuracy is 1/1000
Power supply Between 12 and 24VDC ±10%, floating ratio (P-P): 10% maximum Class 2
Working environment brightness Incandescent: Maximum: 20,000lux, Daylight: Maximum: 30,000lux
Power consumption Standard mode: Maximum 300MW; Maximum voltage: 24V Standard mode: Maximum 300MW; Maximum voltage: 24V
Vibration resistance 10 to 55Hz, dual amplitude: 1.5mm, X, Y, Z axes are 2 hours each
Ambient temperature -10 to +55℃, no freezing
Model NPN NO GFO-CR11-N
PNP NO GFO-CR11-P

 

CR11 fiber optic sensors

Send Inquiry